Joomla Slide Menu by DART Creations

Benefits

Very thin stone Fire Test Data

Class Testing Method Class-Criteria Additional Classific.
A1fl prEN ISO 1182 (1);

And

ΔT ≤ 30°C; und

Δm ≤ 50%; und

tf = 0 (i.e. no continuous burning)

.
prENISO 1716 PCS≤ 2,0 MJ/kg (1)and PCS ≤ 2,0 MJ/kg (2) and PCS ≤ 1,4 MJ/m2 (3)and PCS ≤ 2,0 MJ/kg (4) .
A2fl prEN ISO 1182 (1);

Or

ΔT ≤ 50°C; and

Δm ≤ 50%; and

tf ≤ 20s

.

prEN ISO 1716; and

PCS ≤ 3,0 MJ/kg (1) and PCS ≤ 4,0 MJ/m2 (2) and PCS ≤ 4,0 MJ/m2 (3)and PCS ≤ 3,0 MJ/kg (4)

.

prEN ISO 9239-1 (5)

Critical heatflow (6) ≥ 8,0 kW/m2

Development of smoke (7)

Bfl

prEN ISO 9239-1 (5) und

Critical heatflow (6) ≥ 8,0 kW/m2

Development of smoke (7)

prEN ISO 11925-2 Wear = 15s

Fs ≤ 150mm within 20s

.

Cfl

prEN ISO 9239-1 (5)and

Critical heatflow (6) ≥ 4,5 kW/m2

Development of smoke (7)

prEN ISO 11925-2 (8) Wear = 15s

Fs ≤ 150mm within 20s

.

Dfl

prEN ISO 9239-1 (5) and

Critical heatflow (6) ≥ 3,0 kW/m2

Development of smoke (7)

prEN ISO 11925-2 (8) Wear = 15s

Fs ≤ 150mm within 20s

.

Efl

prEN ISO 11925-2 Wear = 15s Fs ≤ 150mm within 20s

Ffl



-1
For homogenous Building materials and substantial parts of homogenous building materials

-2
For every external part of any homogenous building material

-3
 For every non-substantial component of non-homogenous building materials

-4
For the complete product

-5
Test period = 30 min.

-6
Critical heat flow is the lower of the two figures, or
Heat flow after a test-period of 30 min. (i.e. the figure, which is correspondent with the lowest spread of fire)

-7
s1 = Smoke ? 750% minutes
s2 = not s1

-8
Flame applied to the surface and if valid for the use as an edge-product.